| Features |
| Low insertion loss |
| High channel isolation |
| Low polarization dependence |
| Environmentally stable |
| Applications |
| DWDM systems |
| Fiber optic sensors |
| Subscriber loop |
| CATV |
| Specifications (DWDM) |
| Dense Wavelength Division Multiplexer (100GHz) |
|
Parameter |
Channel Number |
Units |
||||||
| Channel Number | 2 |
4 |
8 |
16 |
32 |
40 |
||
| Start Wavelength | ITU-T Grid |
nm |
||||||
| Passband | Central Wavelength +/-0.11 |
GHz |
||||||
| Channel Passband | Min. | 0.25 |
nm |
|||||
| Passband Flatness | Max. | 0.5 |
dB |
|||||
| Insertion Loss | Typ. | 1.4 |
1.6 |
2.6 |
3.8 |
4.8 |
5.2 |
dB |
| Max. | 1.8 |
2.0 |
3.2 |
4.5 |
5.5 |
6.0 |
dB |
|
| PDL | Max. | 0.10 |
0.15 |
0.20 |
0.25 |
0.30 |
0.30 |
dB |
| PMD | Max. | 0.10 |
0.15 |
ps |
||||
| Directivity | Min. | 50 |
dB |
|||||
| Adjacent Channel Isolation | Min. | 25 |
dB |
|||||
| Non-adjacent Channel Isolation | Min. | 45 |
dB |
|||||
| Return Loss | Min. | 45 |
dB |
|||||
| Wavelength Thermal Stability | Max. | 0.001 |
nm/ºC |
|||||
| Insertion Loss Thermal Stability | Max. | 0.005 |
0.007 |
0.008 |
dB/ºC |
|||
| Operation Temperature | -5 to +65 |
ºC |
||||||
| Storage Temperature | -40 to +85 |
ºC |
||||||
| Dense Wavelength Division Multiplexer (200GHz) |
|
Parameter |
Channel Number |
Units |
|||||
| Channel Number | 2 |
4 |
8 |
16 |
20 |
||
| Start Wavelength | ITU-T Grid |
nm |
|||||
| Passband | Central Wavelength +/-0.25 |
GHz |
|||||
| Channel Passband | Min. | 0.6 |
nm |
||||
| Passband Flatness | Max. | 0.5 |
dB |
||||
| Insertion Loss | Typ. | 1.4 |
1.6 |
2.6 |
3.8 |
4.3 |
dB |
| Max. | 1.8 |
2.0 |
3.2 |
4.5 |
5.0 |
dB |
|
| PDL | Max. | 0.10 |
0.15 |
0.20 |
0.25 |
dB |
|
| PMD | Max. | 0.10 |
0.15 |
ps |
|||
| Directivity | Min. | 50 |
dB |
||||
| Adjacent Channel Isolation | Min. | 25 |
dB |
||||
| Non-adjacent Channel Isolation | Min. | 45 |
dB |
||||
| Return Loss | Min. | 45 |
dB |
||||
| Wavelength Thermal Stability | Max. | 0.002 |
nm/ºC |
||||
| Insertion Loss Thermal Stability | Max. | 0.005 |
0.007 |
0.008 |
dB/ºC |
||
| Operation Temperature | -5 to +65 |
ºC |
|||||
| Storage Temperature | -40 to +85 |
ºC |
|||||
* The specification is for the DWDM without connector. |
| For customized specification on the DWDM, please contact us at contact@optolinkcorp.com. |
| Ordering Codes |
OLDWDM - SD -[Channel Spacing] - [Channel Number] - [Start Wavelength] - [Pigtail Length] - [Connector Type]-[Application Type] |
| Channel Spacing | Code | Channel Number | Code | Start wavelength | Code | Pigtail Length | Code | Connector Type | Code | Application Type | Code |
| 100GHz | 1 | 2 channels | 02 | ITU Grid | XX | Customer Specify | XX |
No Connector |
NC |
MUX | M |
| 200GHz | 2 | 4 channels | 04 |
FC/APC |
FA |
DEMUX | D | ||||
| 8 channels | 08 |
FC/PC |
FP |
MUX and DEMUX | M/D | ||||||
| 16 channels | 16 |
FC/UPC |
FU |
||||||||
| 20 channels | 20 |
SC/APC |
SA |
||||||||
| 32 channels | 32 |
SC/PC |
SP |
||||||||
| 40 channels | 40 |
ST/UPC |
ST |
||||||||
SC/UPC |
SU |
||||||||||
LC/PC |
LP |
||||||||||
LC/UPC |
LU |
||||||||||
MU/PC |
MP |
||||||||||
| * Opto-Link Corporation Ltd reserves the right to make changes to the DWDM without notice. |
|
|||
|
|||
© Opto-Link Corporation Limited 2002-2012. All Rights Reserved. |
|||